Report to: Development Services Committee                               Date of Meeting: June 6, 2006

 

SUBJECT:                          Application for Site Plan Control Approval

                                            Ruland Properties Inc. (The Remington Group)

                                            Phase I Apartment Buildings

                                            Markham Centre

                                            SC 06 107107

 

PREPARED BY:               Richard Kendall, Manager of Development, Central District, Extension 6588

 

 

RECOMMENDATION:

That the report dated June 6, 2006, entitled “Application for Site Plan Control Approval - Ruland Properties Inc. (The Remington Group), Phase I Apartment Buildings, Markham Centre” be received;

 

That the application for site plan control approval by Ruland Properties for a 10-storey and 7-storey apartment building containing 188 units and linked by a common lobby be endorsed in principle, subject to the conditions attached as Appendix A;

 

That site plan approval be delegated to the Director of Planning and Urban Design or her designate, to be issued following execution of a Site Plan Agreement.  Site Plan approval is issued only when the Director has signed the site plan.

That the Owner execute the Markham Centre Landowners Group Agreement and pay their proportionate share of the costs of community infrastructure and facilities prior to final site plan approval to the satisfaction of the Town Solicitor and Commissioner of Development Services;

That the Owner execute a Subdivision Agreement prior to final site plan approval to the satisfaction of the Town Solicitor and Commissioner of Development Services;

That Council authorize the enactment of a by-law to remove the Hold (H) provision on the subject lands upon execution of the Subdivision and Site Plan Agreements to the satisfaction of the Commissioner of Development Services and the Town Solicitor; and,

That the Owner revise the building elevations and site plan to address the concerns raised by staff and the Markham Centre Advisory Committee to the satisfaction of the Commissioner of Development Services.

EXECUTIVE SUMMARY:

Council granted draft plan approval to the Remington Group’s comprehensive, mixed-used project ‘Downtown Markham’ in July, 2003.  This project serves to implement many of the Town’s objectives for Markham Centre, including protecting for the introduction of rapid transit and providing for a variety of development parcels to accommodate a wide range of uses.  The plan anticipates an approximate 20 year plus build-out for the various phases and in July, 2004, the Markham Centre Zoning By-law (2004-196) was enacted to implement the plan. 

 

Since the granting of draft plan approval and enactment of the By-law, the applicant has been working towards addressing certain technical issues associated with the conditions of draft plan approval, prior to executing a subdivision agreement.  Addressing these technical issues will likely result in certain amendments to the conditions of draft plan approval, which will be the subject of a future staff report.  In the meantime, the applicants are proceeding with obtaining phase one site plan approvals to be in a position to finalize building permits, once the subdivision agreement has been executed. 

 

This report recommends the endorsement of the site plan application for the first two (10 and 7-storey) apartment buildings (188 units) within the plan, subject to various conditions, including the finalization of requisite subdivision and site plan agreements and execution of a developer’s group agreement.  An allocation of 800 units has previously been granted to the Remington Group at the time of draft plan approval in 2003.

 

FINANCIAL CONSIDERATIONS:

Not applicable


1. Purpose                2. Background         3. Discussion             4. Financial         5. Environmental

 

6. Accessibility       7. Engage 21st             8. Affected Units       9. Attachment(s)

 

 


PURPOSE:


The purpose of this report is to discuss and make recommendations on an application for site plan control approval by Ruland Properties Inc. for a 10-storey and a 7-storey apartment building within Phase 1 of their Downtown Markham project.  


 

BACKGROUND:


In July, 2003, Council granted draft plan approval to the Remington Group’s comprehensive, mixed-used ‘Downtown Markham’ project.    It is a project which implements many of the Town’s objectives for Markham Centre, including protecting for the introduction of rapid transit through the centre; respecting and enhancing the Rouge River valley; providing for a internal road network; creating a series of new public spaces and urban parks, including a large, urban central park as a new focus for Town-wide activities and celebrations; and, providing for a variety of development parcels to accommodate a wide range of uses. 

 

The plan contributes to achieving the Markham Centre vision though the introduction of up to approximately 362,750 square metres (3,904,736 square feet) of office and business park uses, 33,755 square metres (363,348 square feet) of grade-related retail and up to 3,889 residential units in a medium to high density built form. 

 

The plan, which will be phased, anticipates an approximate 20 year plus, build-out, and provides for a series of residential and mixed-use neighbourhoods and local parks.  Office uses are strategically located within three large blocks between Enterprise Boulevard and Highway 407. 

 

In July, 2004, the Markham Centre Zoning By-law (2004-196) was enacted to implement the plan.  This application represents another significant step in the development of Markham Centre and realizing the Town’s mixed use vision for an urban core.

 

Since the granting of draft plan approval and enactment of the Zoning By-law, the applicant has been working towards addressing certain technical issues associated with the conditions of draft plan approval, prior to executing a subdivision agreement.  Addressing these technical issues will likely result in certain amendments to the conditions of draft plan approval, which will be the subject of a future staff report.  In the meantime, the applicants are proceeding with obtaining phase one site plan approvals to be in a position to finalize building permits, once the subdivision agreement has been executed. 


 

OPTIONS/ DISCUSSION:


Project Description

The applicants are proposing to construct the first two condominium apartment buildings within the multi-building first residential phase of the project.  Overall, the first phase apartment programme provides for 12 apartment buildings and approximately 1,200 units, oriented adjacent to the Civic Mall, along the extension of Birchmount Road and on either side of the future Verclaire Gate extension. 

 

The first two buildings (A and B) will be located at the northeast corner of Enterprise Boulevard and West Valley Drive (Figure 1).  The westerly Building (A) will be 10 storeys and is intended to serve as a gateway stepping down to the east at the ninth and seventh floors (Figure 5).  The second building (B) would be 7 storeys and establish the height pattern for future buildings within this phase.  Additional stepping and articulation will occur at each level of the buildings.

 

The two buildings, which combined will contain 188 units, will be linked by a one storey lobby, and share an underground parking garage.  Access to these buildings will be via the public road network which services the adjacent townhouse blocks.  Key components of this project include a green roof above the common lobby, bike storage facilities within the underground garage, connection to District Energy, and a strong urban edge to the street and adjacent Civic Mall.  Ground floor units will have individual access to outdoor patio spaces to further animate the base of the buildings. 

 

Building materials consist of a combination of brick, precast columns and aluminum windows.   Additional detailing has been introduced to strengthen the building bases.  Building (A) also includes additional glass and aluminum elements on the westerly elevation on the 10th floor to mark the entrance to the residential precinct.  Perimeter landscaping is intended to compliment that proposed for the townhouse blocks to the north and tie-in with streetscape concepts for Enterprise Boulevard and the future park design process for the Civic Mall.

 

 

 

Zoning and Official Plan

The lands are designated Community Amenity Area within the Markham Centre Secondary Plan (OPA 21).  This designation recognizes a range of medium and high density residential uses, including the proposed apartment buildings.  The lands are zoned Markham Centre Downtown Two MC-D2 Zone in the Markham Centre Zoning By-law, which serves to implement the policies in the secondary plan and permits the apartment buildings.  Notwithstanding, minor variances may be required to address certain setback issues with respect to the Civic Mall and the internal road network.  In addition, the applicants are proposing a slight increase in the amount of residential parking to accommodate certain of the larger units within the proposal.  Staff will review this parking request with the consultant who undertook the Markham Centre Parking Strategy, prior to commenting on the minor variance application.

 

Block Build-out Plan has been Submitted

The applicants have provided a comprehensive plan demonstrating the complete build-out of the apartment and associated townhouse blocks within this component of the first residential phase.  This plan (Figure 6) is consistent with the approved precinct plan and demonstrates the applicant’s ability to achieve the densities being requested and address various access, servicing and open space requirements. 

 

Site Plan Process is Proceeding Concurrently with other Technical Approvals

The applicant is working towards finalizing technical approvals associated with the draft plan approval of the larger subdivision.  Resolution of these technical issues will likely result in amendments to the conditions of draft plan approval, which will be the subject of a future staff report to Council.  The applicants are seeking phase one site plan approvals to be in a position to finalize building permits, once the subdivision agreement has been executed.

 

The conditions of site plan approval require the owner to execute a Subdivision Agreement prior to final site plan approval being granted.  It is noted however, that the Toronto and Region Conservation Authority, who the applicants have been working closely with, have advised that they have no objection in principle to the application subject to finalization of the Master Environmental Servicing Plan.

 

Proposal has been Reviewed by the Markham Centre Advisory

The applicant presented this proposal to the Advisory Group at their meeting of April 20, 2006.  The Advisory rated the proposal Gold for its Built Form, Transportation and Green Infrastructure components and Silver for its Open Space elements.  The Greenlands criteria were not considered applicable in this instance.  While commenting that overall, the project was “on-target”, the Advisory requested additional information regarding the green infrastructure initiatives, and would like to assess the landscape elements in the context of the larger block development, with a view to possibly improving the Open Space ranking.  The conditions of site plan approval require the applicant to provide a green infrastructure plan as well as address TDM initiatives associated with the apartment buildings.

 

Applicants are Targeting LEED Certification

In addition to the review of this application through the Markham Centre Advisory, the developers are seeking LEED certification.  Specific measures towards this certification include water reduction through efficient landscaping and green roof technology, use of construction methods and materials to improve air quality, as well as sorting and streaming of construction waste.

 

Departmental / Agency Comments

The Fire Department has identified their requirements for this project which have been addressed in the conditions of approval.

 

The Engineering Department requires site servicing, grading and stormwater management reports prior to final approval.  A Functional Traffic Design Study has been submitted and is currently being reviewed.  Noise and vibration studies will also be required in accordance with the conditions of draft plan approval. 

 

Since the apartment buildings are located adjacent to the Civic Mall, which will eventually accommodate the future dedicated rapid transit alignment, York Region Rapid Transit has requested additional information regarding the design and interface with the transit corridor.  While the timeframe for the introduction of the dedicated transit line has not been determined, it will be important that the design of the Civic Mall “signal” to future purchasers that transit will be located adjacent to their buildings.  This could be achieved in part through the landscape design plan for the Civic Mall, which the Town will be addressing in concert with the Remington Group as part of the Phase 1 subdivision approval.

 

Toronto and Region Conservation Authority (TRCA) has Provided Comments

The TRCA advises that the MESP for this area has not been finalized, with issues pertaining to stormwater management and stormwater infiltration remaining to be resolved.  The Authority notes that this portion of Remington’s development is not adjacent to the Rouge Valley corridor, and would not directly impact upon any significant natural features.  Accordingly, TRCA staff have no objection, in principle, to the proposed site plan applications, subject to the remaining MESP issues being resolved in advance of this development proceeding, and final site plan approval not being provided until the subdivision agreement has been executed.  The conditions of site plan approval reflect this requirement.

 

Servicing Allocation is Available

In concert with the processing of the applications for zoning amendments and draft plan approval, the Town previously granted a servicing allocation of 800 units to the Remington Group.  This allocation was predicated on the applicants up-fronting the cost of constructing Enterprise Boulevard and entering into a Developer’s Group Agreement.  Consequently, allocation is available to this phase of the project.  The conditions of site plan approval require the applicant to enter into the group agreement to ensure they provide their share of the costs associated with community infrastructure and facilities.

 

 


 

FINANCIAL TEMPLATE (Separate Attachment):


Not applicable


 

ENVIRONMENTAL CONSIDERATIONS:

This proposal has been evaluated against the Markham Centre Performance Measures and has been rated “on-target”, and the applicants advise they are seeking LEED certification.  This project is another step in achieving the Markham Centre vision.  While issues of Green Infrastructure will continue to be addressed in concert with the Advisory’s on-going review of this and other applications in Downtown Markham, elements of Green Infrastructure include a green roof on the lobby structure, District Energy connections, and bike storage facilities.

 

ACCESSIBILITY CONSIDERATIONS:

There are no accessibility implications for the Town in this report.

 

ENGAGE 21ST CONSIDERATIONS:

The proposal aligns with the following key Town of Markham Corporate Goals: Managed Growth, Quality Community and Infrastructure Management.

 

BUSINESS UNITS CONSULTED AND AFFECTED:

The applications have been circulated to applicable departments and agencies for comment, and their requirements have been included as conditions of approval.

 

CONCLUSION:

Subject to resolution of subdivision requirements, the apartment buildings represent a significant initial step in the development of Downtown Markham and in achieving the Markham Centre vision of a dynamic, transit supportive, people-friendly and sustainable mixed-use community. 

 

RECOMMENDED BY:

 

 

 

 

 

 

 

 

 

Valerie Shuttleworth, M.C.I.P., R.P.P.

Director of Planning & Urban Design

 

 

Jim Baird, M.C.I.P., R.P.P.

Commissioner of Development Services

 

 

 


 

ATTACHMENTS:


Figure 1:  Site Location

Figure 2:  Area Context and Zoning

Figure 3:  Aerial Photo

Figure 4:  Proposed Site Plan

Figure 5:  Proposed Elevations

Figure 6:  Draft Block Plan

 

APPENDIX A – Conditions of Site Plan Approval

Q:\Development\Planning\Teams\Markham Centre\Coordinator\Remington\Phase 1 Apartment Site Plan\Phase 1 Apartment Site Plan Report.doc



APPENDIX A – CONDITIONS OF SITE PLAN APPROVAL

1.         That prior to final site plan approval the Owner revise the site plan to comply with the applicable zoning, or shall obtain variances for relief from the setback, parking and other requirements of the by-law to accommodate the building programme, as described in this report;

2.         That prior to final site plan approval the Owner provide easements respecting public access connections through the subject lands to the satisfaction of the Commissioner of Development Services and the Town Solicitor;

3.         That prior to final site plan approval the Owner prepare an overall utility plan (Composite Utility Plan) to the satisfaction of the Town for the Phase 1 lands. The plan shall comply with the approved streetscape design criteria for Markham Centre, and minimize the exposure of above grade service structure/equipment to the satisfaction of the Commissioner of Development Services, and that the approved utility plan be included in the material displayed in the sales centre;

4.         That prior to final site plan approval, the Owner enter into an agreement with the Town which shall be registered on title, committing not to enter into any agreements of purchase and sale with anyone, including individuals, other developers or builders, for any units within the plan area unless servicing allocation has been assigned by the Town in consultation with the Markham Centre Landowners Group.  The Owner further agrees to save harmless the Town and Region from any claim or action as a result of servicing capacity not being available when anticipated;

5.       That prior to final site plan approval, the Owner shall submit final drawings including, but not limited to, site plans and elevation drawings, an underground parking layout plan, grading, servicing and engineering drawings that comply with all requirements of the Town and authorized public agencies, to the satisfaction of the Commissioner of Development Services;

6.       That prior to final site plan approval the Owner shall submit a Landscape Plan, including a detailed lighting submission, prepared by a Landscape Architect, having O.A.L.A. membership for approval by the Commissioner of Development Services, prior to the execution of the site plan agreement;

7.         That the Owner enter into a Site Plan Agreement with the Town, containing all standard and special provisions and requirements of the Town and other public agencies, including MTO and York Region; and, including the specific requirements identified in the staff report, prior to final site plan approval;

 

8.       That the Owner satisfy cash-in-lieu of parkland obligations for the apartment buildings, in accordance with the Parkland Principles for Markham Centre and pursuant to the Markham Centre Secondary Plan and the Markham Centre Developers Group Agreement, to the satisfaction of the Commissioner of Development Services.

9.       That the Owner pay its proportionate share of development charges in accordance with Area Specific Development Charge By-laws;

10.       That the location, size and construction of all refuse storage areas and recycling facilities, and arrangements for waste collection be to the satisfaction of the Town of Markham Waste Management Department;

11.       That provisions for Fire Routes, yard hydrants, Siamese connections and other emergency access requirements be to the satisfaction of the Fire Department;

12.       That provision for snow removal and storage, sidewalk alignment and maintenance be to the satisfaction of the General Manager of Operations and Director of Engineering;

13.       That the Owner provide and implement a detailed stormwater management plan, including quality control measures/devices, as well as provide noise and vibration studies to the satisfaction of the Director of Engineering;

14.       That the Owner comply with all requirements of the Town and authorized public agencies, including PowerStream, to the satisfaction of the Commissioner of Development Services;

15.       That the Owner provide confirmation that height and lighting of the buildings meets the requirements of Transport Canada, including applicable warning clauses;

16.       That the Owner provide confirmation that they have addressed the requirements of York Region Rapid Transit, including grading and landscaping details;

17.       That the Owner provide and implement a TDM plan which clearly identifies bike parking, and any other measures to promote alternative modes to the single occupant vehicle;

18.       That the Owner provide and implement a comprehensive Green Infrastructure plan, which includes the introduction of green roof technology on the lobby building and provides for connection to the District Energy network, to the satisfaction of the Commissioner of Development Services;

19.       That the Owner participate in the enhanced hoarding programme, and that staff be authorized to enter into a Hoarding Agreement with the Owner;

20.       That any Town support for minor variances to the oversupply of parking be site specific in nature, only associated with the larger residential (2 bedroom +) units and, subject to a parking demand study;